  • Air quality sensor for monitoring the indoor air quality
  • Non-dispersive infrared (NDIR) gas sensor with CO2 measurement range up to 5000 ppm
  • Ventilation advice based on CO2 concentration in the air
  • Indoor temperature display in ° C or ° F
  • Indoor humidity display
  • MIN / MAX value memory for the last 24 hours with automatic scrolling function
  • 2 adjustable values ​​for CO2 level exceeding. Warning with flashing symbols and optional alarm sound
  • Adjustable high or low humidity warning
  • Calibration function for CO2, temperature and humidity
  • Low battery indicator
  • Built-in ROM memory to store settings
  • Backlight with adjustable brightness levels
  • Standing table

CO2 levels and guidelines
  • Below are some common CO2 reference levels:
  • 400 ~ 600 ppm - Background (normal) outside air level.
  • 600 ~ 1,000 ppm - Typical level for occupied areas with good air circulation.
  • 1,000 ~ 1,500 ppm - Start ventilation of the room.
  • 1,500 ~ 2,000 ppm - Level associated with complaints of drowsiness and bad air. Ventilation recommended!
  • 2,000 ~ 5,000 ppm - Level associated with headache, drowsiness, and stagnant, stale, congested air. Poor concentration, loss of attention, increased heart rate and mild nausea can also occur. Ventilation strongly recommended!
  • > 5,000 ppm - Exposure can lead to severe oxygen starvation, which can lead to permanent brain damage, coma and death. Requires immediate ventilation!

Specifications
  • Dimensions: 94 x 145 x 50 mm
  • Power supply: Power supply (included)
  • Temperature range: 0 ° C - 50 ° C / 32 ° F to 122 ° F
  • Temperature resolution: 0.1 ° C
  • Humidity range: 20% - 95% RH
  • Humidity resolution: 1%
  • Operating temperature: 0 ° C to 50 ° C / 32 ° F to 122 ° F <95%, non-condensing

CO2
  • Measuring range: 400 - 5000PPM
  • Resolution: 1 PPM
  • Accuracy: +/- 5% + 50PPM
  • Warm-up time: 1 minute
  • Display out of range CO2:
  • 400 (= 400PPM)
  • HI (= 5000PPM)
  • Temperature:
  • LO (= 0 ° C / 32 ° F).
  • HI (= 50 ° C / 122 ° F).
  • Humidity:
  • 20% (= 20%)
  • 95% (= 95%)
  • Standard settings
  • CO2 alarm: low -400, high 2000
  • RH% Alarm: Low 35%, High 70%.
  • CO2 audible alarm: Off
  • Temperature: ° C
  • Display brightness level: high