TL WL1030 CO2 luchtkwaliteit meetstation

Technoline CO2 meetstation met instelbare alarmwaardes. Werkt op netspanning

TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
TL WL1030 CO2 luchtkwaliteit meetstation
77.50 *Price shown incl. NL VAT | Checkout adjusts to Country choosen VAT.
Manufacturer Technoline
Article codeTE-WL1030

On stock

Discount scheme
  • 1 = € 77.50
  • 20+ = € 69.00

Description
  • Air quality sensor for monitoring the indoor air quality
  • Non-dispersive infrared (NDIR) gas sensor with CO2 measurement range up to 5000 ppm
  • Ventilation advice based on CO2 concentration in the air
  • Indoor temperature display in ° C or ° F
  • Indoor humidity display
  • MIN / MAX value memory for the last 24 hours with automatic scrolling function
  • 2 adjustable values ​​for CO2 level exceeding. Warning with flashing symbols and optional alarm sound
  • Adjustable high or low humidity warning
  • Calibration function for CO2, temperature and humidity
  • Low battery indicator
  • Built-in ROM memory to store settings
  • Backlight with adjustable brightness levels
  • Standing table

CO2 levels and guidelines
  • Below are some common CO2 reference levels:
  • 400 ~ 600 ppm - Background (normal) outside air level.
  • 600 ~ 1,000 ppm - Typical level for occupied areas with good air circulation.
  • 1,000 ~ 1,500 ppm - Start ventilation of the room.
  • 1,500 ~ 2,000 ppm - Level associated with complaints of drowsiness and bad air. Ventilation recommended!
  • 2,000 ~ 5,000 ppm - Level associated with headache, drowsiness, and stagnant, stale, congested air. Poor concentration, loss of attention, increased heart rate and mild nausea can also occur. Ventilation strongly recommended!
  • > 5,000 ppm - Exposure can lead to severe oxygen starvation, which can lead to permanent brain damage, coma and death. Requires immediate ventilation!

Specifications
  • Dimensions: 94 x 145 x 50 mm
  • Power supply: Power supply (included)
  • Temperature range: 0 ° C - 50 ° C / 32 ° F to 122 ° F
  • Temperature resolution: 0.1 ° C
  • Humidity range: 20% - 95% RH
  • Humidity resolution: 1%
  • Operating temperature: 0 ° C to 50 ° C / 32 ° F to 122 ° F <95%, non-condensing

CO2
  • Measuring range: 400 - 5000PPM
  • Resolution: 1 PPM
  • Accuracy: +/- 5% + 50PPM
  • Warm-up time: 1 minute
  • Display out of range CO2:
  • 400 (= 400PPM)
  • HI (= 5000PPM)
  • Temperature:
  • LO (= 0 ° C / 32 ° F).
  • HI (= 50 ° C / 122 ° F).
  • Humidity:
  • 20% (= 20%)
  • 95% (= 95%)
  • Standard settings
  • CO2 alarm: low -400, high 2000
  • RH% Alarm: Low 35%, High 70%.
  • CO2 audible alarm: Off
  • Temperature: ° C
  • Display brightness level: high

Features and Specifications

Merken Technoline

All Tags